10-36kv Power Transmission Cabinet Ring Main Unit Switchgear

Product Details
Customization: Available
Type: Distribution Metering Box
Structure: Protection
Still deciding? Get samples of US$ 800/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
85
Year of Establishment
2014-04-01
  • 10-36kv Power Transmission Cabinet Ring Main Unit Switchgear
  • 10-36kv Power Transmission Cabinet Ring Main Unit Switchgear
  • 10-36kv Power Transmission Cabinet Ring Main Unit Switchgear
  • 10-36kv Power Transmission Cabinet Ring Main Unit Switchgear
  • 10-36kv Power Transmission Cabinet Ring Main Unit Switchgear
  • 10-36kv Power Transmission Cabinet Ring Main Unit Switchgear
Find Similar Products

Basic Info.

Model NO.
10KV-24kv /630A/20KA
Certification
ISO9001:2000, CCC
Form
Partly-welded Type
Operation Voltage
High Voltage
Size
1 Uint
Application Range
Power Plants
Shell Material
Stainless Steel
Shell Protection Grade
IP67
Brand
Anhao
Lead Tme
15-30days
Transport Package
Plywood Cases
Specification
160kg
Trademark
AH-SRM-12/24
Origin
Guangdong, China
Production Capacity
20000 Units/Per Years

Product Description

12/24kv high voltage SF6 gas insulated switchgear gis ring main unit switchgear

10-36kv Power Transmission Cabinet Ring Main Unit Switchgear
 
 
Main Application
The SF6 gas insulated switchgear (GIS) is used for receiving and distributing electric energy in power system. It is widely used in processing industry, civil  and power supply terminal,such as:

· Small secondary distribution station
· Switching station
· Urban residential area
· Airport
· Railway, tunnel



Product Features

· The switchgear is equipped with perfect "Five Prevention" interlock device, which can completely eliminate personnel injury and equipment operation failure caused by human error operation.

· The gas insulated switchgear uses SF6 gas as arc extinguishing and insulating medium

· The switchgear is fully sealed and insulated, and the protection level reaches IP67.

· The switchgear has reliable safe pressure relief channel, which can guarantee the safety of personnel even in extreme cases

· The whole switchgear is not affected by the external environment.

· Cabinet size is small, does not occupy space, and easy to install

· The switchgear can be equipped with electric, remote control and detection devices according to different needs of users




Technical Parameters
 
12kv Technical  Parameter Unit C module F module V module CB module
Load
break
switch
Switch
fuse
Vacuum
circuit
breaker
Isolate/
earthing switch
Vacuum
circuit
breaker
Isolate/
earthing
switch
Rated Voltage KV 12 12 12 12 12 12
Rated Frequency HZ 50 50 50 50 50 50
Power Frequence Withstand Voltage KV 42 42 42 42 42 42
Impulse Withstand Voltage KV 75/85 75/85 75/85 75/85 75/85 75/85
Rated Current A 630 1250 630 630    
Closed Loop A 630          
Off Load Cable Charging A 10          
Rated Active Load Drop-oput Current A 630 630        
When Earth Fault Frop out Current of Cable Charging A 17.4          
Short Circuit Drop-out Current KA   31.5 25      
Making Capacity KA 50 note 63 63 63 63
Rated Short Time Withstand Current KA/3S 20   20 20 25 25
Transfer Current A   1700        
Loop Resistance μΩ ≤300 ≤600        
Mechanical Life Times 5000 5000 10000 3000 10000 3000

24kv Technical  Parameter Unit C module F module V module CB module
Load
break
switch
Switch
fuse
Vacuum
circuit
breaker
Isolate/
earthing switch
Vacuum
circuit
breaker
Isolate/
earthing switch
Rated Voltage KV 24 24 24 24 24 24
Rated Frequency HZ 50 50 50 50 50 50
Power Frequence Withstand Voltage KV 65 65 65 65 65 65
Impulse Withstand Voltage KV 125 125 125 125 125 125
Rated Current A 630 125 630      
Closed Loop A 630          
Off Load Cable Charging A 10          
Rated Active Load Drop-oput Current A 31.5 630        
When Earth Fault Frop out Current of Cable Charging A 43.3          
Short Circuit Drop-out Current KA     20 20 25  
Making Capacity KA 50   50 50 63 63
Rated Short Time Withstand Current KA/3S 20   16 16 20 20
Transfer Current A   1400        
Loop Resistance μΩ ≤300 ≤600        
Mechanical Life Times 5000 5000 10000 10000 10000 5000




Common Used Programme
10-36kv Power Transmission Cabinet Ring Main Unit Switchgear

10-36kv Power Transmission Cabinet Ring Main Unit Switchgear
 
 
Applicable conditions

Altitude:≤2000m
Ambient temperature:-35ºC~+40ºC
Relative humidity:
Daily average≤95%
Monthly average≤90%
Seismic capacity:8 degrees
 



Product Photo

10-36kv Power Transmission Cabinet Ring Main Unit Switchgear10-36kv Power Transmission Cabinet Ring Main Unit Switchgear10-36kv Power Transmission Cabinet Ring Main Unit Switchgear10-36kv Power Transmission Cabinet Ring Main Unit Switchgear




Company Profile

10-36kv Power Transmission Cabinet Ring Main Unit Switchgear



Workshop Corner
10-36kv Power Transmission Cabinet Ring Main Unit Switchgear



Testing Equipments

10-36kv Power Transmission Cabinet Ring Main Unit Switchgear


10-36kv Power Transmission Cabinet Ring Main Unit Switchgear
10-36kv Power Transmission Cabinet Ring Main Unit Switchgear






 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier